Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss
This 1U on-line double-conversion UPS system with battery-independent restart maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SUINT1500LCD1U provides the highest level of power protection and battery backup for servers, switches, phone systems, kiosks and professional A/V computer systems in IT applications where rack space is limited and a 1U UPS is desired.
Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA internal battery allows you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting.
Optional LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.
C13 Outlets Protect Your Connected Components
Five C13 outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The outlets are grouped into two individually controllable load banks that let you shed non-critical loads to extend runtime for critical loads.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.
Clear LCD Interface Keeps You Informed at a Glance
The menu-driven front-panel LCD provides detailed settings, alarms and notifications to help diagnose any issues. It provides voltage, frequency, battery, load and other critical information. Audible alarms can be disabled through the front menu when the UPS goes to battery power. LEDs indicate AC output status and shutdown/fault condition.
Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The EPO/ROO port permits emergency shutdown or remote restart of all connected equipment.
Needs Only 1U of Rack Space for Installation
You can mount the SUINT1500LCD1U in just 1U of space in an EIA-standard 19-inch 4-post rack using the included hardware. The six-foot (1.8-meter) power cord with C14 plug connects to a compatible AC outlet. An internal fan helps keep the UPS cool in a crowded enclosure.
- General Information
- Manufacturer
- Tripp Lite by Eaton
- Manufacturer Website Address
- https://tripplite.eaton.com/
- Brand Name
- Tripp Lite by Eaton
- Product Line
- SmartOnline
- Product Type
- Double Conversion Online UPS
- Warranty
- Limited Warranty
- 2 Year
- Technical Information
- Plug/Connector Type
- IEC 60320 C14
- Receptacle Type
- IEC 60320 C13
- Receptacle Detail
- 5 x IEC 60320 C13
- EMI/RFI Noise Filter
- Yes
- Phase
- Single Phase
- Energy Saving
- Green Energy-Saving
- Application/Usage
- Mission Critical Equipment
- IT
- Server
- Switch
- Phone
- Kiosk
- Data Center
- Computer Room
- Industrial
- Automation Industry
- Network Equipment
- Power Description
- Load Capacity (VA)
- 1500 VA
- Load Capacity (Watt)
- 1440 W
- Input Voltage
- 230 V AC
- Output Voltage
- 200 V AC
- 208 V AC
- 230 V AC
- 220 V AC
- 240 V AC
- Input Frequency
- 60 Hz
- Output Frequency
- 60 Hz
- Waveform Type
- Pure Sine Wave
- Surge Energy Rating
- 540 J
- Output Power Factor
- 0.96
- Display & Graphics
- Display
- LCD
- Management
- Network Management
- SNMP/Web
- DB-9 RS-232
- Alarm
- Power Failure
- Low Battery
- Overload
- Fault
- Controls/Indicators
- Status Indicators
LED Indicators:
- AC Output
- Shutdown / Fault
- Interfaces/Ports
- Serial Port
- Yes
- USB
- Yes
- EPO Port
- Yes
- USB (HID Compliant) Port
- Yes
- Battery Information
- DC System Voltage
- 48 V DC
- Battery Characteristics
- Valve-regulated
- Battery Chemistry
- Lead Acid
- Backup/Run Time (Full Load)
- 3 Minute
- Backup/Run Time (Half Load)
- 10 Minute
- Hot Swappable
- Yes
- Replaceable Battery
- Yes
- Environmental Conditions
- Minimum Operating Temperature
- 32°F (0°C)
- Maximum Operating Temperature
- 104°F (40°C)
- Storage Temperature
- 5°F (-15°C) - 122°F (50°C)
- Maximum Operating Elevation
- 3280.84 ft
- Sound Emission (A-Weighted)
- 65 dB(A)
- Thermal Dissipation
- 234.16 W
- Physical Characteristics
- Height
- 1.7"
- Width
- 17.3"
- Depth
- 28"
- Rack Height
- 1U
- Form Factor
- Rack-mountable
- Weight (Approximate)
- 45.19 lb
- Miscellaneous
- Package Contents
- SmartOnline SUINT1500LCD1U 1500VA Rack-mountable UPS
- USB Cable
- DB9 Cable
- Rack-mounting Hardware
- Owner's Manual
- Back Panel Grounding Lug
- 2 x C13 to C14 Power Cables
- Environmentally Friendly
- Yes
- Environmental Compliance
- Restriction of Hazardous Substances (RoHS)